Part Numbers & Accessories

Microhard N920X2数传电台配置点对点高速通信

主:
+++
AT&F6
AT&WA

从:
+++
AT&F7
AT&WA

Microhard N920X2数传电台配置点对点低速通信

主:
+++
AT&F8
AT&WA

从:
+++
AT&F9
AT&WA

Microhard N920X2数传电台配置点对多点高速通信

主:
+++
AT&F1
AT&WA

中继:
+++
AT&F3
AT&WA

从:
+++
AT&F2
AT&WA

Microhard N920X2数传电台配置点对多点低速通信

主:
+++
AT&F4
AT&WA

从1:
+++
AT&F5
AT&WA

从2:
+++
AT&F5
ATS105=3 //修改自己的ID
AT&WA

Microhard N920X2数传电台配置从与从通信

Master
• enter into Command Mode
• load the &F1 factory default settings
• change the Network Type (S133) to 2
• change Packet Retransmissions (S113) from 5 to 0 (increase from 0 if re-quired)
• save the change using the AT&W command
• go online with the ATA command

Slave 1
• enter into Command Mode
• load the &F2 factory default settings
• change the Network Type (S133) to 2
• change the Destination Address (S140) to 3 (to be the UA of Slave 2)

• save the change using the AT&W command
• go online with the ATA command

Slave 2
• enter into Command Mode
• load the &F2 factory default settings
• change the Network Type (S133) to 2
• change the Unit Address (S105) to 3
• change the Destination Address (S140) to 2 (the UA of Slave 1)

• save the change using the AT&W command
• go online with the ATA command

Microhard N920X2数传电台配置相互广播通信

Master
• enter into Command Mode
• load the &F1 factory default settings
• change the Network Type (S133) to 2
• change Packet Retransmissions (S113) from 5 to 0 (increase from 0 if re-quired)
• save the change using the AT&W command
• go online with the ATA command

Slaves
• enter into Command Mode
• load the &F2 factory default settings
• change the Network Type (S133) to 2
• change the Unit Address (S105) to a unique number (range: 2-65534)
• change the Destination Address(S140) to 65535 (the broadcast address)
• save the change using the AT&W command
• go online with the ATA command